SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-GG0GGD-P-A-DK00000 Advanced Energy CX10S-GG0GGD-P-A-DK00000 -
RFQ
ECAD 3421 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG0GGD-P-A-DK00000 EAR99 8504.40.9540 1 680W 9 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 3 A 3 A
CX10S-DGB0HB-P-A-DK00000 Advanced Energy CX10S-DGB0HB-P-A-DK00000 -
RFQ
ECAD 1714 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGB0HB-P-A-DK00000 EAR99 8504.40.9540 1 780W 7 93% 48V 24V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 15 A 6 A 3 A
CX10S-HDCGDD-P-A-DK00000 Advanced Energy CX10S-HDCGDD-P-A-DK00000 -
RFQ
ECAD 1299 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HDCGDD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 8 93% 5V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 8.3 A 3 A 3 A
CX10S-00CGCD-P-A-DK00000 Advanced Energy CX10S-00CGCD-P-A-DK00000 -
RFQ
ECAD 5624 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00CGCD-P-A-DK00000 EAR99 8504.40.9540 1 720W 5 93% 24V 24V 24V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 8.3 A 4.17 A
CX10S-0D0D0B-P-A-DK00000 Advanced Energy CX10S-0D0D0B-P-A-DK00000 -
RFQ
ECAD 1427 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0D0D0B-P-A-DK00000 EAR99 8504.40.9540 1 580W 3 93% 48V 48V 12V - - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 15 A
CX10S-GHG0CA-P-A-DK00000 Advanced Energy CX10S-GHG0CA-P-A-DK00000 -
RFQ
ECAD 8543 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHG0CA-P-A-DK00000 EAR99 8504.40.9540 1 645W 8 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-0GHDGH-P-A-DK00000 Advanced Energy CX10S-0GHDGH-P-A-DK00000 -
RFQ
ECAD 2065 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GHDGH-P-A-DK00000 EAR99 8504.40.9540 1 640W 9 93% 24V 24V 5V 24V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 4.17 A 3 A
CX10S-GHG0BC-P-A-DK00000 Advanced Energy CX10S-GHG0BC-P-A-DK00000 -
RFQ
ECAD 7411 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHG0BC-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-0D0DAD-P-A-DK00000 Advanced Energy CX10S-0D0DAD-P-A-DK00000 -
RFQ
ECAD 6408 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0D0DAD-P-A-DK00000 EAR99 8504.40.9540 1 705W 4 93% 48V 48V 5V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 4.17 A 21 A 4.17 A
CX10S-0DBABB-P-A-DK00000 Advanced Energy CX10S-0DBABB-P-A-DK00000 -
RFQ
ECAD 9646 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DBABB-P-A-DK00000 EAR99 8504.40.9540 1 845W 5 93% 48V 12V 5V 12V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 15 A 21 A 15 A 15 A
CX10S-GG0HAH-P-A-DK00000 Advanced Energy CX10S-GG0HAH-P-A-DK00000 -
RFQ
ECAD 1492 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GG0HAH-P-A-DK00000 EAR99 8504.40.9540 1 545W 9 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 6 A 3 A
CX10S-00BD0H-P-A-DK00000 Advanced Energy CX10S-00BD0H-P-A-DK00000 -
RFQ
ECAD 9352 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00BD0H-P-A-DK00000 EAR99 8504.40.9540 1 480W 4 93% 12V 48V 5V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 6 A 3 A
CX10S-GHA0AA-P-A-DK00000 Advanced Energy CX10S-GHA0AA-P-A-DK00000 -
RFQ
ECAD 9491 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHA0AA-P-A-DK00000 EAR99 8504.40.9540 1 535W 7 93% 24V 24V 5V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 21 A 21 A
CX10S-DCADBA-P-A-DK00000 Advanced Energy CX10S-DCADBA-P-A-DK00000 -
RFQ
ECAD 6667 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DCADBA-P-A-DK00000 EAR99 8504.40.9540 1 990W 6 93% 48V 24V 5V 48V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 21 A 4.17 A 15 A 21 A
CX10S-GB0AGA-P-A-DK00000 Advanced Energy CX10S-GB0AGA-P-A-DK00000 -
RFQ
ECAD 7659 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GB0AGA-P-A-DK00000 EAR99 8504.40.9540 1 630W 7 93% 24V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 21 A 3 A 3 A
CX10S-GHG0H0-P-A-DK00000 Advanced Energy CX10S-GHG0H0-P-A-DK00000 -
RFQ
ECAD 5413 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GHG0H0-P-A-DK00000 EAR99 8504.40.9540 1 440W 8 93% 24V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 6 A 3 A 3 A 3 A
CX10S-AACAGD-P-A-DK00000 Advanced Energy CX10S-AACAGD-P-A-DK00000 -
RFQ
ECAD 6828 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AACAGD-P-A-DK00000 EAR99 8504.40.9540 1 835W 7 93% 5V 5V 24V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 21 A 3 A 3 A
CX10S-00HDHA-P-A-DK00000 Advanced Energy CX10S-00HDHA-P-A-DK00000 -
RFQ
ECAD 2107 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00HDHA-P-A-DK00000 EAR99 8504.40.9540 1 505W 6 93% 5V 24V 48V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 4.17 A 6 A 3 A 21 A
CX10S-ACD0AH-P-A-DK00000 Advanced Energy CX10S-ACD0AH-P-A-DK00000 -
RFQ
ECAD 1180 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACD0AH-P-A-DK00000 EAR99 8504.40.9540 1 510W 6 93% 5V 24V 48V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 4.17 A 21 A 6 A 3 A
CX10S-AH0CCC-P-A-DK00000 Advanced Energy CX10S-AH0CCC-P-A-DK00000 -
RFQ
ECAD 9131 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AH0CCC-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 5V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 8.3 A 8.3 A 8.3 A
CX10S-A0ACHA-P-A-DK00000 Advanced Energy CX10S-A0ACHA-P-A-DK00000 -
RFQ
ECAD 8231 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0ACHA-P-A-DK00000 EAR99 8504.40.9540 1 615W 6 93% 5V 5V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 8.3 A 6 A 3 A 21 A
CX10S-AAHCHG-P-A-DK00000 Advanced Energy CX10S-AAHCHG-P-A-DK00000 -
RFQ
ECAD 6086 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AAHCHG-P-A-DK00000 EAR99 8504.40.9540 1 730W 9 93% 5V 5V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 6 A 3 A 8.3 A 6 A
CX10S-0DCGBB-P-A-DK00000 Advanced Energy CX10S-0DCGBB-P-A-DK00000 -
RFQ
ECAD 6377 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DCGBB-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 24V 24V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 3 A 3 A 15 A 15 A
CX10S-0C0CHB-P-A-DK00000 Advanced Energy CX10S-0C0CHB-P-A-DK00000 -
RFQ
ECAD 3185 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0C0CHB-P-A-DK00000 EAR99 8504.40.9540 1 680W 5 93% 24V 24V 5V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 6 A 3 A 15 A
CX10S-AGDGAC-P-A-DK00000 Advanced Energy CX10S-AGDGAC-P-A-DK00000 -
RFQ
ECAD 9933 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGDGAC-P-A-DK00000 EAR99 8504.40.9540 1 850W 8 93% 5V 24V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 4.17 A 3 A 3 A
CX10S-0GBDAB-P-A-DK00000 Advanced Energy CX10S-0GBDAB-P-A-DK00000 -
RFQ
ECAD 6481 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GBDAB-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 24V 24V 12V 48V 5V 12V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 4.17 A 21 A 15 A
CX10S-AHBD0A-P-A-DK00000 Advanced Energy CX10S-AHBD0A-P-A-DK00000 -
RFQ
ECAD 5651 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AHBD0A-P-A-DK00000 EAR99 8504.40.9540 1 690W 6 93% 5V 5V 24V 12V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 15 A 4.17 A 21 A
CX10S-00DABB-P-A-DK00000 Advanced Energy CX10S-00DABB-P-A-DK00000 -
RFQ
ECAD 1698 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-00DABB-P-A-DK00000 EAR99 8504.40.9540 1 665W 4 93% 48V 5V 12V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 21 A 15 A 15 A
CX10S-0GD0BD-P-A-DK00000 Advanced Energy CX10S-0GD0BD-P-A-DK00000 -
RFQ
ECAD 5947 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GD0BD-P-A-DK00000 EAR99 8504.40.9540 1 700W 5 93% 24V 24V 48V 12V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 15 A 4.17 A
CX10S-ACHHD0-P-A-DK00000 Advanced Energy CX10S-ACHHD0-P-A-DK00000 -
RFQ
ECAD 5569 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACHHD0-P-A-DK00000 EAR99 8504.40.9540 1 505W 7 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 6 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse