Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-HHCBAA-P-A-DK00000 Advanced Energy CX10S-HHCBAA-P-A-DK00000 -
RFQ
ECAD 8965 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHCBAA-P-A-DK00000 EAR99 8504.40.9540 1 790W 8 93% 5V 24V 5V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 8.3 A 15 A
CX10S-A0A0BC-P-A-DK00000 Advanced Energy CX10S-A0A0BC-P-A-DK00000 -
RFQ
ECAD 6401 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0A0BC-P-A-DK00000 EAR99 8504.40.9540 1 590W 4 93% 5V 5V 12V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 15 A 8.3 A
CX10S-000CCG-P-A-DK00000 Advanced Energy CX10S-000CCG-P-A-DK00000 -
RFQ
ECAD 3665 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000CCG-P-A-DK00000 EAR99 8504.40.9540 1 520W 4 93% 24V 24V 24V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 3 A 3 A
CX10S-ADDDDC-P-A-DK00000 Advanced Energy CX10S-ADDDDC-P-A-DK00000 -
RFQ
ECAD 5096 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADDDDC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 6 93% 5V 48V 48V 48V 48V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 4.17 A 4.17 A 4.17 A 8.3 A
CX10S-AGBCHG-P-A-DK00000 Advanced Energy CX10S-AGBCHG-P-A-DK00000 -
RFQ
ECAD 7663 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AGBCHG-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 5V 24V 24V 12V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 3 A 3 A 15 A 8.3 A 6 A
CX10S-ADH0HB-P-A-DK00000 Advanced Energy CX10S-ADH0HB-P-A-DK00000 -
RFQ
ECAD 5310 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADH0HB-P-A-DK00000 EAR99 8504.40.9540 1 685W 7 93% 5V 48V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 6 A 3 A 6 A 3 A
CX10S-0CBHBA-P-A-DK00000 Advanced Energy CX10S-0CBHBA-P-A-DK00000 -
RFQ
ECAD 6145 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CBHBA-P-A-DK00000 EAR99 8504.40.9540 1 765W 6 93% 24V 12V 5V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 6 A 3 A 15 A 21 A
CX10S-AC0CGC-P-A-DK00000 Advanced Energy CX10S-AC0CGC-P-A-DK00000 -
RFQ
ECAD 7838 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AC0CGC-P-A-DK00000 EAR99 8504.40.9540 1 625W 6 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 8.3 A 3 A 3 A 8.3 A
CX10S-CCAHHC-P-A-DK00000 Advanced Energy CX10S-CCAHHC-P-A-DK00000 -
RFQ
ECAD 2954 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CCAHHC-P-A-DK00000 EAR99 8504.40.9540 1 905W 8 93% 24V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 21 A 6 A 3 A 6 A
CX10S-0CCA00-P-A-DK00000 Advanced Energy CX10S-0CCA00-P-A-DK00000 -
RFQ
ECAD 1064 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0CCA00-P-A-DK00000 EAR99 8504.40.9540 1 505W 3 93% 24V 24V 5V - - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 21 A
CX10S-CHB0HG-P-A-DK00000 Advanced Energy CX10S-CHB0HG-P-A-DK00000 -
RFQ
ECAD 5418 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHB0HG-P-A-DK00000 EAR99 8504.40.9540 1 700W 8 93% 24V 5V 24V 12V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 15 A 6 A 3 A
CX10S-CGBDBH-P-A-DK00000 Advanced Energy CX10S-CGBDBH-P-A-DK00000 -
RFQ
ECAD 4962 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CGBDBH-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 24V 24V 12V 48V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 3 A 3 A 15 A 4.17 A 15 A
CX10S-0AA0H0-P-A-DK00000 Advanced Energy CX10S-0AA0H0-P-A-DK00000 -
RFQ
ECAD 2460 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0AA0H0-P-A-DK00000 EAR99 8504.40.9540 1 310W 4 93% 5V 5V 5V 24V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 21 A 6 A 3 A
CX10S-000GGD-P-A-DK00000 Advanced Energy CX10S-000GGD-P-A-DK00000 -
RFQ
ECAD 1019 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-000GGD-P-A-DK00000 EAR99 8504.40.9540 1 440W 5 93% 24V 24V 24V 24V 48V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 4.17 A
CX10S-CC0DCA-P-A-DK00000 Advanced Energy CX10S-CC0DCA-P-A-DK00000 -
RFQ
ECAD 6158 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CC0DCA-P-A-DK00000 EAR99 8504.40.9540 1 905W 5 93% 24V 24V 48V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 8.3 A 4.17 A 8.3 A 21 A
CX10S-BCAGHH-P-A-DK00000 Advanced Energy CX10S-BCAGHH-P-A-DK00000 -
RFQ
ECAD 5634 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCAGHH-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 12V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 21 A 3 A 3 A 6 A
CX10S-ABBA0G-P-A-DK00000 Advanced Energy CX10S-ABBA0G-P-A-DK00000 -
RFQ
ECAD 9426 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ABBA0G-P-A-DK00000 EAR99 8504.40.9540 1 690W 6 93% 5V 12V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 15 A 21 A 3 A 3 A
CX10S-GGHDGG-P-A-DK00000 Advanced Energy CX10S-GGHDGG-P-A-DK00000 -
RFQ
ECAD 3993 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GGHDGG-P-A-DK00000 EAR99 8504.40.9540 1 780W 11 93% 24V 24V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 6 A 3 A
CX10S-GCHADA-P-A-DK00000 Advanced Energy CX10S-GCHADA-P-A-DK00000 -
RFQ
ECAD 3686 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCHADA-P-A-DK00000 EAR99 8504.40.9540 1 830W 8 93% 24V 24V 24V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 6 A 3 A 21 A
CX10S-CBDGBH-P-A-DK00000 Advanced Energy CX10S-CBDGBH-P-A-DK00000 -
RFQ
ECAD 2082 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CBDGBH-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 12V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 15 A 4.17 A 3 A 3 A 15 A
CX10S-DC0D0D-P-A-DK00000 Advanced Energy CX10S-DC0D0D-P-A-DK00000 -
RFQ
ECAD 9325 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DC0D0D-P-A-DK00000 EAR99 8504.40.9540 1 800W 4 93% 48V 24V 48V 48V - - No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 4.17 A 4.17 A
CX10S-0BDDCC-P-A-DK00000 Advanced Energy CX10S-0BDDCC-P-A-DK00000 -
RFQ
ECAD 8773 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0BDDCC-P-A-DK00000 EAR99 8504.40.9540 1 980W 5 93% 12V 48V 48V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 15 A 4.17 A 4.17 A 8.3 A 8.3 A
CX10S-ADAAH0-P-A-DK00000 Advanced Energy CX10S-ADAAH0-P-A-DK00000 -
RFQ
ECAD 9938 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADAAH0-P-A-DK00000 EAR99 8504.40.9540 1 615W 6 93% 5V 48V 5V 5V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 21 A 21 A 6 A 3 A
CX10S-C0DB0A-P-A-DK00000 Advanced Energy CX10S-C0DB0A-P-A-DK00000 -
RFQ
ECAD 6682 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-C0DB0A-P-A-DK00000 EAR99 8504.40.9540 1 685W 4 93% 24V 48V 12V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 4.17 A 15 A 21 A
CX10S-G0BHGC-P-A-DK00000 Advanced Energy CX10S-G0BHGC-P-A-DK00000 -
RFQ
ECAD 2189 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0BHGC-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 24V 24V 12V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 6 A 3 A 3 A
CX10S-GBB0B0-P-A-DK00000 Advanced Energy CX10S-GBB0B0-P-A-DK00000 -
RFQ
ECAD 7574 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBB0B0-P-A-DK00000 EAR99 8504.40.9540 1 660W 5 93% 24V 24V 12V 12V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 15 A 15 A
CX10S-G0GCCC-P-A-DK00000 Advanced Energy CX10S-G0GCCC-P-A-DK00000 -
RFQ
ECAD 2545 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0GCCC-P-A-DK00000 EAR99 8504.40.9540 1 840W 7 93% 24V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 8.3 A 8.3 A
CX10S-BCCB00-P-A-DK00000 Advanced Energy CX10S-BCCB00-P-A-DK00000 -
RFQ
ECAD 9282 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BCCB00-P-A-DK00000 EAR99 8504.40.9540 1 760W 4 93% 12V 24V 24V 12V - - No 4 kV 60601-1; 60950-1; 62368-1 15 A 8.3 A 8.3 A 15 A
CX10S-GC0DBC-P-A-DK00000 Advanced Energy CX10S-GC0DBC-P-A-DK00000 -
RFQ
ECAD 3639 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GC0DBC-P-A-DK00000 EAR99 8504.40.9540 1 700W 6 93% 24V 24V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 4.17 A 15 A 8.3 A
CX10S-GABGHB-P-A-DK00000 Advanced Energy CX10S-GABGHB-P-A-DK00000 -
RFQ
ECAD 6243 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GABGHB-P-A-DK00000 EAR99 8504.40.9540 1 805W 9 93% 24V 24V 5V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 15 A 3 A 3 A