SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Type Features Base Product Number Approval Agency Voltage - Input DataSheet REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Minimum Load Required Voltage - Isolation Standard Number Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6
CX10S-0GGBCG-P-A-DK00000 Advanced Energy CX10S-0GGBCG-P-A-DK00000 -
RFQ
ECAD 7505 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0GGBCG-P-A-DK00000 EAR99 8504.40.9540 1 740W 8 93% 24V 24V 24V 24V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 3 A 3 A 15 A 8.3 A
CX10S-BAHAGG-P-A-DK00000 Advanced Energy CX10S-BAHAGG-P-A-DK00000 -
RFQ
ECAD 5704 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BAHAGG-P-A-DK00000 EAR99 8504.40.9540 1 730W 9 93% 12V 5V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 21 A 6 A 3 A 21 A 3 A
CX10S-0ABCBB-P-A-DK00000 Advanced Energy CX10S-0ABCBB-P-A-DK00000 -
RFQ
ECAD 1545 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ABCBB-P-A-DK00000 EAR99 8504.40.9540 1 845W 5 93% 5V 12V 24V 12V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 15 A 8.3 A 15 A 15 A
CX10S-GCBDHB-P-A-DK00000 Advanced Energy CX10S-GCBDHB-P-A-DK00000 -
RFQ
ECAD 6900 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GCBDHB-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 24V 24V 24V 12V 48V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 8.3 A 15 A 4.17 A 6 A
CX10S-GAGHHD-P-A-DK00000 Advanced Energy CX10S-GAGHHD-P-A-DK00000 -
RFQ
ECAD 7711 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAGHHD-P-A-DK00000 EAR99 8504.40.9540 1 745W 10 93% 24V 24V 5V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 3 A 3 A 6 A
CX10S-AD0DBG-P-A-DK00000 Advanced Energy CX10S-AD0DBG-P-A-DK00000 -
RFQ
ECAD 8066 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AD0DBG-P-A-DK00000 EAR99 8504.40.9540 1 805W 6 93% 5V 48V 48V 12V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 4.17 A 15 A 3 A 3 A
CX10S-0ACH0G-P-A-DK00000 Advanced Energy CX10S-0ACH0G-P-A-DK00000 -
RFQ
ECAD 5155 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0ACH0G-P-A-DK00000 EAR99 8504.40.9540 1 525W 6 93% 5V 24V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 6 A 3 A 3 A 3 A
CX10S-CH0DCC-P-A-DK00000 Advanced Energy CX10S-CH0DCC-P-A-DK00000 -
RFQ
ECAD 5533 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CH0DCC-P-A-DK00000 EAR99 8504.40.9540 1 900W 6 93% 24V 5V 24V 48V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 4.17 A 8.3 A 8.3 A
CX10S-BBBDHC-P-A-DK00000 Advanced Energy CX10S-BBBDHC-P-A-DK00000 -
RFQ
ECAD 1097 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BBBDHC-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 12V 12V 12V 48V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 15 A 15 A 4.17 A 6 A 3 A
CX10S-AD0GAA-P-A-DK00000 Advanced Energy CX10S-AD0GAA-P-A-DK00000 -
RFQ
ECAD 1172 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-AD0GAA-P-A-DK00000 EAR99 8504.40.9540 1 635W 6 93% 5V 48V 24V 24V 5V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 3 A 3 A 21 A 21 A
CX10S-ADDC0B-P-A-DK00000 Advanced Energy CX10S-ADDC0B-P-A-DK00000 -
RFQ
ECAD 8541 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADDC0B-P-A-DK00000 EAR99 8504.40.9540 1 885W 5 93% 5V 48V 48V 24V 12V 5V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 4.17 A 8.3 A 15 A
CX10S-G0DHCH-P-A-DK00000 Advanced Energy CX10S-G0DHCH-P-A-DK00000 -
RFQ
ECAD 7929 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-G0DHCH-P-A-DK00000 EAR99 8504.40.9540 1 720W 8 93% 24V 24V 48V 5V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 4.17 A 6 A 3 A 8.3 A
CX10S-A0HDBC-P-A-DK00000 Advanced Energy CX10S-A0HDBC-P-A-DK00000 -
RFQ
ECAD 4290 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-A0HDBC-P-A-DK00000 EAR99 8504.40.9540 1 785W 6 93% 5V 5V 24V 48V 12V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 6 A 3 A 4.17 A 15 A 8.3 A
CX10S-0B0HCG-P-A-DK00000 Advanced Energy CX10S-0B0HCG-P-A-DK00000 -
RFQ
ECAD 9486 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0B0HCG-P-A-DK00000 EAR99 8504.40.9540 1 600W 6 93% 12V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 8.3 A 3 A 3 A
CX10S-HGGDG0-P-A-DK00000 Advanced Energy CX10S-HGGDG0-P-A-DK00000 -
RFQ
ECAD 6849 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HGGDG0-P-A-DK00000 EAR99 8504.40.9540 1 660W 9 93% 5V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 3 A 3 A 3 A 3 A
CX10S-DGGC0G-P-A-DK00000 Advanced Energy CX10S-DGGC0G-P-A-DK00000 -
RFQ
ECAD 2724 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-DGGC0G-P-A-DK00000 EAR99 8504.40.9540 1 760W 8 93% 48V 24V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 3 A 3 A 3 A 3 A 8.3 A
CX10S-ADCGDA-P-A-DK00000 Advanced Energy CX10S-ADCGDA-P-A-DK00000 -
RFQ
ECAD 8222 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADCGDA-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 5V 48V 24V 24V 24V 48V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 8.3 A 3 A 3 A 4.17 A
CX10S-ACDGCA-P-A-DK00000 Advanced Energy CX10S-ACDGCA-P-A-DK00000 -
RFQ
ECAD 7347 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ACDGCA-P-A-DK00000 EAR99 8504.40.9540 1 930W 7 93% 5V 24V 48V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 8.3 A 4.17 A 3 A 3 A 8.3 A
CX10S-ADH0GD-P-A-DK00000 Advanced Energy CX10S-ADH0GD-P-A-DK00000 -
RFQ
ECAD 5742 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADH0GD-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 5V 48V 5V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 6 A 3 A 3 A 3 A
CX10S-ADB00A-P-A-DK00000 Advanced Energy CX10S-ADB00A-P-A-DK00000 -
RFQ
ECAD 5960 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-ADB00A-P-A-DK00000 EAR99 8504.40.9540 1 590W 4 93% 5V 48V 12V 5V - - No 4 kV 60601-1; 60950-1; 62368-1 21 A 4.17 A 15 A 21 A
CX10S-0DCBGB-P-A-DK00000 Advanced Energy CX10S-0DCBGB-P-A-DK00000 -
RFQ
ECAD 1657 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-0DCBGB-P-A-DK00000 EAR99 8504.40.9540 1 880W 6 93% 48V 24V 12V 24V 24V 12V No 4 kV 60601-1; 60950-1; 62368-1 4.17 A 8.3 A 15 A 3 A 3 A 15 A
CX10S-GAHA0A-P-A-DK00000 Advanced Energy CX10S-GAHA0A-P-A-DK00000 -
RFQ
ECAD 2163 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GAHA0A-P-A-DK00000 EAR99 8504.40.9540 1 535W 7 93% 24V 24V 5V 5V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 6 A 3 A 21 A
CX10S-HHBBBH-P-A-DK00000 Advanced Energy CX10S-HHBBBH-P-A-DK00000 -
RFQ
ECAD 7928 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HHBBBH-P-A-DK00000 EAR99 8504.40.9540 1 840W 9 93% 5V 24V 5V 24V 12V 12V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 15 A 15 A
CX10S-GADBDG-P-A-DK00000 Advanced Energy CX10S-GADBDG-P-A-DK00000 -
RFQ
ECAD 1088 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GADBDG-P-A-DK00000 EAR99 8504.40.9540 1 925W 8 93% 24V 24V 5V 48V 12V 48V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 21 A 4.17 A 15 A 4.17 A
CX10S-HACHGC-P-A-DK00000 Advanced Energy CX10S-HACHGC-P-A-DK00000 -
RFQ
ECAD 2840 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-HACHGC-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 5V 24V 5V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 21 A 8.3 A 6 A 3 A
CX10S-GBG0AD-P-A-DK00000 Advanced Energy CX10S-GBG0AD-P-A-DK00000 -
RFQ
ECAD 8658 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-GBG0AD-P-A-DK00000 EAR99 8504.40.9540 1 725W 7 93% 24V 24V 12V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 3 A 3 A 15 A 3 A 3 A 21 A
CX10S-H0HADG-P-A-DK00000 Advanced Energy CX10S-H0HADG-P-A-DK00000 -
RFQ
ECAD 6523 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-H0HADG-P-A-DK00000 EAR99 8504.40.9540 1 625W 8 93% 5V 24V 5V 24V 5V 48V No 4 kV 60601-1; 60950-1; 62368-1 6 A 3 A 6 A 3 A 21 A 4.17 A
CX10S-CHGHAD-P-A-DK00000 Advanced Energy CX10S-CHGHAD-P-A-DK00000 -
RFQ
ECAD 6658 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CHGHAD-P-A-DK00000 EAR99 8504.40.9540 1 825W 9 93% 24V 5V 24V 24V 24V 5V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 6 A 3 A 3 A 3 A 6 A
CX10S-BHCHCD-P-A-DK00000 Advanced Energy CX10S-BHCHCD-P-A-DK00000 -
RFQ
ECAD 3937 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-BHCHCD-P-A-DK00000 EAR99 8504.40.9540 1 980W 8 93% 12V 5V 24V 24V 5V 24V No 4 kV 60601-1; 60950-1; 62368-1 15 A 6 A 3 A 8.3 A 6 A 3 A
CX10S-CACCGD-P-A-DK00000 Advanced Energy CX10S-CACCGD-P-A-DK00000 -
RFQ
ECAD 8702 0.00000000 Advanced Energy COOLX®1000 Box Active -40°C ~ 85°C ITE (Commercial), Medical 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) Chassis Mount Enclosed Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input CX10S CSA, EN, IEC, UL 85 ~ 264 VAC download REACH Affected 633-CX10S-CACCGD-P-A-DK00000 EAR99 8504.40.9540 1 1000W 7 93% 24V 5V 24V 24V 24V 24V No 4 kV 60601-1; 60950-1; 62368-1 8.3 A 21 A 8.3 A 8.3 A 3 A 3 A
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse