SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Mounting Type Material Features Base Product Number Includes Accessory Type Color For Use With/Related Products Termination Ingress Protection Note Style DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Connector Type Number of Rows Contact Finish Contact Finish Thickness Current Rating (Amps) Cable Type Orientation Shielding Contact Material Material Flammability Rating Contact Type Pitch - Mating Number of Positions Row Spacing - Mating Number of Positions Loaded Shrouding Fastening Type Contact Length - Mating Contact Length - Post Overall Contact Length Insulation Height Contact Shape Contact Finish - Mating Contact Finish Thickness - Mating Contact Finish - Post Insulation Material Insulation Color Voltage Rating Mated Stacking Heights Contact Finish Thickness - Post Mounting Feature Mating Cycles Plating Flange Feature Dielectric Material Shell Size - Insert Shell Size, MIL Primary Material Shell Material Shell Finish Cable Opening Backshell Material, Plating Insert Material Housing Color Convert From (Adapter End) Convert To (Adapter End) Shell Material, Finish Connector Style Wire Gauge Contact Form Shell Size, Connector Layout Backset Spacing Shell Finish Thickness Cable Exit Hardware
192-037-113-531 NorComp Inc. 192-037-113-531 -
RFQ
ECAD 3752 0.00000000 NorComp Inc. 192 - Obsolete -55°C ~ 125°C Panel Mount, Through Hole, Right Angle Board Lock, Grounding Indents, Shielded 192-037 Black Solder - download RoHS non-compliant Not Applicable REACH Unaffected 192037113531 EAR99 8536.69.4040 80 Plug, Male Pins 2 Gold Flash 5A Brass UL94 V-0 Signal 37 - Housing/Shell (4-40) Polyester Thermoplastic Steel, Nickel Plated D-Sub - Stamped 4 (DC, C) 0.370" (9.40mm)
192-015-213-531 NorComp Inc. 192-015-213-531 -
RFQ
ECAD 4647 0.00000000 NorComp Inc. 192 - Obsolete -55°C ~ 125°C Panel Mount, Through Hole, Right Angle Board Lock, Shielded 192-015 Black Solder - download RoHS non-compliant Not Applicable REACH Unaffected 192015213531 EAR99 8536.69.4040 140 Receptacle, Female Sockets 2 Gold Flash 5A Phosphor Bronze UL94 V-0 Signal 15 - Housing/Shell (4-40) Polyester Thermoplastic Steel, Nickel Plated D-Sub - Stamped 2 (DA, A) 0.370" (9.40mm)
26641201RP2 NorComp Inc. 26641201RP2 1.4700
RFQ
ECAD 7437 0.00000000 NorComp Inc. 2664 Bulk Active -40°C ~ 105°C - Through Hole - Solder - Board to Board or Cable download ROHS3 Compliant Not Applicable REACH Unaffected 2664S-06 EAR99 8536.69.4040 100 Header 2 1A Copper Alloy UL94 V-0 Male Pin 0.079" (2.00mm) 12 0.079" (2.00mm) All Unshrouded Push-Pull 0.150" (3.81mm) 0.118" (3.00mm) 0.327" (8.30mm) 0.059" (1.50mm) Square Gold Flash Gold Polyamide (PA6T), Nylon 6T Black - - Flash
180-015-273L010 NorComp Inc. 180-015-273L010 3.7600
RFQ
ECAD 2203 0.00000000 NorComp Inc. 180 Tray Active -50°C ~ 100°C Free Hanging (In-Line) - 180-015 - - Contacts Not Included download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8538.90.8180 90 Receptacle for Female Contacts 3 Signal 15 - Cable Side (4-40) - Steel, Nickel Plated D-Sub, High Density 1 (DE, E) High Density -
160-000-137-000 NorComp Inc. 160-000-137-000 -
RFQ
ECAD 1848 0.00000000 NorComp Inc. - Bulk Obsolete - Cap (Cover), Dust D-Sub Connectors, Male download RoHS non-compliant Not Applicable REACH Unaffected 160-37M EAR99 8538.90.8180 1,000 37
821BR06-213R001 NorComp Inc. 821BR06-213R001 49.6617
RFQ
ECAD 6154 0.00000000 NorComp Inc. QUIK-LOQ™ 821B Tray Active -40°C ~ 200°C Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Panel Mount, Through Hole, Right Angle Board Guide 821B Black, Silver Solder IP50 - Dust Protected download ROHS3 Compliant 1 (Unlimited) REACH Unaffected NOR1549 EAR99 8536.69.4020 30 Receptacle, Female Sockets 7A Keyed Shielded Copper Alloy - 6 Push-Pull Gold 7.00µin (0.178µm) 350V Bulkhead - Front Side Nut - - Metal Brass Nickel - - Polyphenylene Sulfide (PPS)
172-050-213R021 NorComp Inc. 172-050-213R021 13.1523
RFQ
ECAD 6098 0.00000000 NorComp Inc. 172, M Series Tray Active -50°C ~ 100°C Panel Mount, Through Hole - Beige Solder - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 37-172-050-213R021 EAR99 8536.69.4040 20 Receptacle, Female Sockets 3 Gold Flash 5A Brass UL94 V-0 Signal 50 500V Board Side (4-40) Polyamide (PA6T), Nylon 6T Metal Steel, Nickel Plated D-Sub - Machined 5 (DD, D) -
172-015-113R001 NorComp Inc. 172-015-113R001 4.8500
RFQ
ECAD 80 0.00000000 NorComp Inc. 172, M Series Tray Active -50°C ~ 100°C Panel Mount, Through Hole Grounding Indents Beige Solder - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 37-172-015-113R001 EAR99 8536.69.4040 40 Plug, Male Pins 2 Gold Flash 5A Brass UL94 V-0 Signal 15 500V Housing/Shell (Unthreaded) Polyamide (PA6T), Nylon 6T Metal Steel, Nickel Plated D-Sub - Machined 2 (DA, A) -
681S17W2203L001 NorComp Inc. 681S17W2203L001 15.8136
RFQ
ECAD 8181 0.00000000 NorComp Inc. Seal-D 681S Tray Active -55°C ~ 155°C Panel Mount, Through Hole - 681S17W Black Solder IP67 - Dust Tight, Waterproof download ROHS3 Compliant 1 (Unlimited) REACH Unaffected NOR1247 EAR99 8536.69.4040 50 Receptacle, Female Sockets 2 Gold Flash 5A, 20/40A Copper Alloy UL94 V-0 Signal and Power 17 (15 + 2 Power) - Housing/Shell (Unthreaded) Polybutylene Terephthalate (PBT) Steel, Nickel Plated D-Sub, Combo - - 3 (DB, B) - 17W2 -
172-E25-111-001 NorComp Inc. 172-E25-111-001 -
RFQ
ECAD 9563 0.00000000 NorComp Inc. 172-E - Obsolete -50°C ~ 100°C Panel Mount, Through Hole - 172-E25 White Solder - download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8536.69.4040 100 Plug, Male Pins 2 Gold Flash 5A - UL94 V-0 Signal 25 - Housing/Shell (Unthreaded) Polybutylene Terephthalate (PBT), Glass Filled Steel, Yellow Chromate Plated D-Sub - Machined 3 (DB, B) -
CDFV7W2113L211 NorComp Inc. CDFV7W2113L211 13.9500
RFQ
ECAD 50 0.00000000 NorComp Inc. NANOOK Tray Active -25°C ~ 85°C Panel Mount, Through Hole Grounding Indents CDFV7W2 Black Solder IP67 - Dust Tight, Waterproof download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 37-CDFV7W2113L211 EAR99 8536.69.4040 54 Plug, Male Pins 2 Gold Flash 5A, 20A Brass UL94 V-0 Signal and Power 7 (5 + 2 Power) - Mating Side, Female Screwlock (4-40) Polybutylene Terephthalate (PBT) Steel, Nickel Plated D-Sub, Combo - Machined 2 (DA, A) - 7W2 -
180-026-112-021 NorComp Inc. 180-026-112-021 -
RFQ
ECAD 9500 0.00000000 NorComp Inc. 180 - Obsolete -50°C ~ 100°C Panel Mount, Through Hole Grounding Indents 180-026 Black Solder - download RoHS non-compliant Not Applicable REACH Unaffected 8826M EAR99 8536.69.4040 120 Plug, Male Pins 3 Gold Flash 2A - UL94 V-0 Signal 26 - Board Side (4-40) Polyester, Glass Filled Steel, Tin Plated D-Sub, High Density - - 2 (DA, A) High Density -
978-015-020-121 NorComp Inc. 978-015-020-121 -
RFQ
ECAD 4256 0.00000000 NorComp Inc. 978 Bulk Obsolete Plastic, Metallized Mating Screws 4-40 Two Piece Backshell Silver download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8538.90.8180 100 Round Shielded 15 Nickel over Copper 180° Assembly Hardware, Strain Relief
172-050-141-021 NorComp Inc. 172-050-141-021 -
RFQ
ECAD 6049 0.00000000 NorComp Inc. 172 - Obsolete -50°C ~ 100°C Panel Mount, Through Hole - 172-050 Beige Wire Wrap - download RoHS non-compliant Not Applicable REACH Unaffected 6650M EAR99 8536.69.4040 32 Plug, Male Pins 3 Gold Flash 5A - UL94 V-0 Signal 50 - Board Side (4-40) Polybutylene Terephthalate (PBT) Steel, Yellow Chromate Plated D-Sub - Machined 5 (DD, D) -
180-015-172L030 NorComp Inc. 180-015-172L030 -
RFQ
ECAD 5947 0.00000000 NorComp Inc. 180 Tray Obsolete -50°C ~ 100°C Free Hanging (In-Line) Shielded - - Contacts Not Included download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8538.90.8180 160 Plug for Male Contacts 3 Signal 15 - Mating Side (4-40) - Steel, Tin Plated D-Sub, High Density 1 (DE, E) High Density -
GCHDLP62M62F NorComp Inc. GCHDLP62M62F 32.0400
RFQ
ECAD 91 0.00000000 NorComp Inc. GCLP Tray Active -55°C ~ 105°C Panel Mount - GCHDLP6 3 pcs - 1 Connector, 2 Jack Screws - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.8000 40 3 Gold Flash 3 A - UL94 V-0 Yellow D-Sub, 62 HD, Male D-Sub, 62 HD, Female Steel, Tin Plated Connector Saver
822B016-103R001 NorComp Inc. 822B016-103R001 52.4990
RFQ
ECAD 8189 0.00000000 NorComp Inc. QUIK-LOQ™ 822B Tray Active -40°C ~ 200°C - Panel Mount - 822B Silver Solder Cup IP50 - Dust Protected download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4020 20 Plug, Male Pins 6A Keyed Shielded Copper Alloy - 16 Push-Pull Gold 7.00µin (0.178µm) 315V Bulkhead - Rear Side Nut - - Metal Brass Nickel 0.531" (13.50mm) - Polyphenylene Sulfide (PPS)
172-015-213R001 NorComp Inc. 172-015-213R001 6.2500
RFQ
ECAD 33 0.00000000 NorComp Inc. 172, M Series Tray Active -50°C ~ 100°C Panel Mount, Through Hole - Beige Solder - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 37-172-015-213R001 EAR99 8536.69.4040 40 Receptacle, Female Sockets 2 Gold Flash 5A Brass UL94 V-0 Signal 15 500V Housing/Shell (Unthreaded) Polyamide (PA6T), Nylon 6T Metal Steel, Nickel Plated D-Sub - Machined 2 (DA, A) -
180-015-203L001 NorComp Inc. 180-015-203L001 3.3800
RFQ
ECAD 2 0.00000000 NorComp Inc. 180 Tray Active -50°C ~ 100°C Panel Mount Shielded 180-015 - Solder Cup - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.8000 50 Receptacle, Female Sockets 3 Gold Flash 5A Brass UL94 V-0 Signal 15 - Housing/Shell (Unthreaded) Polybutylene Terephthalate (PBT) Steel, Nickel Plated D-Sub, High Density - - 1 (DE, E) High Density -
172-025-112-021 NorComp Inc. 172-025-112-021 -
RFQ
ECAD 1292 0.00000000 NorComp Inc. 172 - Obsolete -50°C ~ 100°C Panel Mount, Through Hole Grounding Indents 172-025 Black Solder - download RoHS non-compliant Not Applicable REACH Unaffected 3525M EAR99 8536.69.4040 80 Plug, Male Pins 2 Gold Flash 5A - UL94 V-0 Signal 25 - Board Side (4-40) Polybutylene Terephthalate (PBT) Steel, Tin Plated D-Sub - Machined 3 (DB, B) -
180-026-201L031 NorComp Inc. 180-026-201L031 -
RFQ
ECAD 5475 0.00000000 NorComp Inc. 180 Tray Obsolete -50°C ~ 100°C Panel Mount Shielded 180-026 - Solder Cup - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 6826FEA EAR99 8536.69.8000 300 Receptacle, Female Sockets 3 Gold Flash 5A Brass UL94 V-0 Signal 26 - Mating Side (4-40) Polybutylene Terephthalate (PBT) Steel, Yellow Chromate Plated D-Sub, High Density - Stamped 2 (DA, A) High Density -
172-050-182-011 NorComp Inc. 172-050-182-011 -
RFQ
ECAD 5655 0.00000000 NorComp Inc. 172 - Obsolete -50°C ~ 100°C Panel Mount, Through Hole Grounding Indents 172-050 - Solder - download RoHS non-compliant Not Applicable REACH Unaffected 13650M EAR99 8536.69.4040 40 Plug, Male Pins 3 Gold Flash 5A - UL94 V-0 Signal 50 - Board Side (4-40) Polybutylene Terephthalate (PBT) Steel, Tin Plated D-Sub - - 5 (DD, D) -
180-026-112-031 NorComp Inc. 180-026-112-031 -
RFQ
ECAD 9634 0.00000000 NorComp Inc. 180 - Obsolete -50°C ~ 100°C Panel Mount, Through Hole Grounding Indents 180-026 Black Solder - download RoHS non-compliant Not Applicable REACH Unaffected 9826M EAR99 8536.69.4040 120 Plug, Male Pins 3 Gold Flash 2A - UL94 V-0 Signal 26 - Mating Side (4-40) Polyester, Glass Filled Steel, Tin Plated D-Sub, High Density - - 2 (DA, A) High Density -
186-025-192-001 NorComp Inc. 186-025-192-001 -
RFQ
ECAD 4031 0.00000000 NorComp Inc. 186 - Obsolete -50°C ~ 100°C Panel Mount Feed Through, Grounding Indents, Strain Relief 186-025 - IDC, Ribbon Cable - download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8536.69.4051 100 Plug, Male Pins 2 Gold Flash 1A - UL94 V-0 Signal 25 - Housing/Shell (Unthreaded) Polybutylene Terephthalate (PBT) Steel, Tin Plated D-Sub - - 3 (DB, B) -
979-009-030-121 NorComp Inc. 979-009-030-121 -
RFQ
ECAD 6172 0.00000000 NorComp Inc. 979 Bulk Obsolete Metal, Zinc Alloy Mating Screws 4-40 Two Piece Backshell Silver download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8538.90.8180 100 Round Shielded 9 Nickel 180° Assembly Hardware, Grommets
191-025-113L561 NorComp Inc. 191-025-113L561 3.6906
RFQ
ECAD 6656 0.00000000 NorComp Inc. 191 Tray Active -55°C ~ 125°C Panel Mount, Through Hole Board Lock, Grounding Indents, Shielded 191-025 Black Solder - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4040 50 Plug, Male Pins 2 Gold Flash 5A Brass UL94 V-0 Signal 25 - Housing/Shell (4-40) Polyester Thermoplastic Steel, Nickel Plated D-Sub - - 3 (DB, B) -
979-037-030-121 NorComp Inc. 979-037-030-121 -
RFQ
ECAD 4085 0.00000000 NorComp Inc. 979 Bulk Obsolete Metal, Zinc Alloy Mating Screws 4-40 Two Piece Backshell Silver download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8538.90.8180 50 Round Shielded 37 Nickel 180° Assembly Hardware, Grommets
970-015-020-121 NorComp Inc. 970-015-020-121 -
RFQ
ECAD 3917 0.00000000 NorComp Inc. 970 Bulk Obsolete Plastic, Metallized Mating Screws 4-40 Two Piece Backshell Silver download RoHS non-compliant Not Applicable REACH Unaffected 970-15MP EAR99 8538.90.8180 200 Round Shielded 15 Nickel over Copper 180° Assembly Hardware, Grommets
180-M15-213R911 NorComp Inc. 180-M15-213R911 8.6000
RFQ
ECAD 2 0.00000000 NorComp Inc. 180-M, M Series Tray Active -55°C ~ 125°C Panel Mount, Through Hole Board Lock, Shielded 180-M15 Black Solder - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4040 90 Receptacle, Female Sockets 3 Gold Flash 5A Copper Alloy UL94 V-0 Signal 15 - Board Side (4-40); Mating Side, Female Screwlock (4-40) Polyamide (PA9T), Nylon 9T Steel, Nickel Plated D-Sub, High Density - Machined 1 (DE, E) High Density -
6803W3K103L401 NorComp Inc. 6803W3K103L401 -
RFQ
ECAD 3820 0.00000000 NorComp Inc. 680 Tray Obsolete -55°C ~ 125°C Panel Mount Grounding Indents 6803W3 - Solder Cup - - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.8000 70 Plug, Male Pins 1 Gold Flash 40A Brass UL94 V-0 Power 3 (Power) - Housing/Shell (Unthreaded) Polybutylene Terephthalate (PBT) Steel, Nickel Plated D-Sub, Combo - - 2 (DA, A) - 3W3 -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse